| Schedule | DN | OD in | Wall in | ID in | Plain-end lb/ft | Check |
|---|---|---|---|---|---|---|
| no schedule | 150 | 6.625 | 0.083 | 6.459 | 5.80 | checked |
| Sch 5 | 150 | 6.625 | 0.109 | 6.407 | 7.59 | checked |
| no schedule | 150 | 6.625 | 0.125 | 6.375 | 8.69 | checked |
| Sch 10 | 150 | 6.625 | 0.134 | 6.357 | 9.30 | checked |
| no schedule | 150 | 6.625 | 0.141 | 6.343 | 9.77 | checked |
| no schedule | 150 | 6.625 | 0.156 | 6.313 | 10.79 | checked |
| no schedule | 150 | 6.625 | 0.172 | 6.281 | 11.87 | checked |
| no schedule | 150 | 6.625 | 0.188 | 6.249 | 12.94 | checked |
| no schedule | 150 | 6.625 | 0.203 | 6.219 | 13.94 | checked |
| no schedule | 150 | 6.625 | 0.219 | 6.187 | 15.00 | checked |
| no schedule | 150 | 6.625 | 0.250 | 6.125 | 17.04 | checked |
| Sch 40 / STD | 150 | 6.625 | 0.280 | 6.065 | 18.99 | checked |
| no schedule | 150 | 6.625 | 0.312 | 6.001 | 21.06 | checked |
| no schedule | 150 | 6.625 | 0.344 | 5.937 | 23.10 | check source |
| no schedule | 150 | 6.625 | 0.375 | 5.875 | 25.05 | formula only |
| Sch 80 / XS | 150 | 6.625 | 0.432 | 5.761 | 28.60 | checked |
| no schedule | 150 | 6.625 | 0.500 | 5.625 | 32.74 | checked |
| Sch 120 | 150 | 6.625 | 0.562 | 5.501 | 36.43 | checked |
| no schedule | 150 | 6.625 | 0.625 | 5.375 | 40.09 | formula only |
| Sch 160 | 150 | 6.625 | 0.719 | 5.187 | 45.39 | checked |
| no schedule | 150 | 6.625 | 0.750 | 5.125 | 47.10 | check source |
| XXS | 150 | 6.625 | 0.864 | 4.897 | 53.21 | checked |
| no schedule | 150 | 6.625 | 0.875 | 4.875 | 53.78 | formula only |
no schedule, wall 0.083 in
Pipe values follow the 2004 editions of B36.10M and B36.19M and flange values and pressure-temperature ratings the 2025 editions of B16.5 and B16.47, fitting values the 2012 edition of B16.9, metallic gaskets the 2012 edition of B16.20 and non-metallic gaskets the 2011 edition of B16.21. Each row is checked by script: pipe against the plain-end weight formula and independent sources, flanges and fittings against the standard’s own SI and U.S. tables. Rows marked “formula only”, “check source” or [UNVERIFIED] have not been fully cross-checked. Mass in kg/m is calculated, not read from the standard. Confirm against the current edition of the standard before use in design or procurement.